成在线人av免费无码高潮喷水,二级av,久久蜜桃视频,亚洲AV无码成人一区二区三区

網(wǎng)站首頁(yè)產(chǎn)品展示burkertburkert電磁閥 > 6144burkert 6144 FKM密封膜片寶帝6144電磁閥
burkert 6144 FKM密封膜片寶帝6144電磁閥

burkert 6144 FKM密封膜片寶帝6144電磁閥

產(chǎn)品型號(hào): 6144

所屬分類:burkert電磁閥

更新日期:2024-04-05

簡(jiǎn)要描述:burkert 6144 FKM密封膜片寶帝6144電磁閥 Type 6144 is a direct-action 3/2-way solenoid valve designed for neutral gases and liquids. Through the movement between the 2 end positions

詳細(xì)說(shuō)明:

burkert 6144 FKM密封膜片寶帝6144電磁閥 Type 6144 is a direct-action 3/2-way solenoid valve designed for neutral gases and liquids. Through the movement between the 2 end positions, the switching element (fl ipper) seals one of the two opposing valve seats and connects the other to the working port.burkert 6144 FKM密封膜片寶帝6144電磁閥 This movement is caused by the solenoids magnetic fi eld pushing a permanent magnet that is fi xed to the fl ipper element. In addition to its exceptional performance characteristics, the fl ipper principle is especially marked by its very low switching noise and its low wear level. Furthermore, integrated medium separation enables use above and beyond pneumatic applications. 

特點(diǎn):

  1. 直動(dòng)式
  2. 0 至 10 bar
  3. 低電功率消耗
  4. 法蘭接頭
  5. 設(shè)計(jì)寬度為 10mm /串接尺寸為 11mm

參數(shù):

Body material PPS (Polyphenylensulfi de)
Seal material FKM
Media Compressed air lubricated, oil-free or dry; neutral
gases and liquids (5μm fi ltering); technical vacuum
Media temperature 0 to +55°C
Ambient temperature 0 to +55°C

Port connection · Bürkert fl ange
· Lateral fl ange
Electrical connection Rectangular plug as standard; on request:
· Circular plug M8x1
· Flying lead 0.2 mm2, 300 mm
· Blank connector (5.08 mm)
Type of protection
Standard version
Ex version

without
II 2G Ex ia IIC T4 T5 T6 PTB01 ATEX 2048
IECEx PTB 07.0063
Operating voltage 24V/DC1) 12V/DC1) on request
Further voltages on request

Voltage tolerance ±10%2) (Further voltages on request)
Nominal power 0.8W
Switching function Monostable
Bistable (impulse) on request
Duty cycle 100% continuous rating
Installation As required, preferably with actuator upright;
5mm minimum distance to ferromagnetic materials

Insulation class 3 acc. VDE 0580
Protection class IP 40, IP 65 by fl ying leads (without hand lever)
Cycling rate ca. 1000/min
Electrical control with SPS possible